M-Thermo Panel R6 – 19 (U Value 0.88 – 0.30)

Eliminate cold bridging – Class A Thermal Sandwich Panel.

AC 90 – ICC ESL 1116 certified Fiber Cement.

Non Structural, underlayment sandwich panel.  

Having insulation exterior moves the dew point further to the exterior wall which helps prevent moisture buildup inside the walls.  This enhances a wall’s ability to prevent water vapor from condensing inside the wall and adds to a structure’s internal energy efficiency.

Fire rating - Panel

Delivering 15 min. Thermal Class A fire rating (CAN/ULC S124-06)

Insulation value

  • R6 (U value 0.88)
  • R13 (U Value 0.44)
  • R19 (U Value 0.30)

Insulation material thickness:  R6 1” (25mm) – R13 2” 50 mm – R19 3” (70 mm).

Application

Easily apply to Stick build/SIPs /Cementous Exterior walls, Subfloors and Exterior roof application. This product serves a multitude of uses as underlayment as well as  an alternative to apply one step, single layer stucco directly to the surface.

Materials

Surface: FC-H20 Fiber Cement (complying with ICC-ES AC 90 – Report ICC ESL 1116): Non Combustible (ASTM E136). Anti water coated front – will repel water. Applicable Building Code: 2015 IBC & 2015 IRC, 2014 Florida Building Code and Florida Residential Code, 2013 California Building Code. (thickness 3/8” – 9mm). The FC-H20 board is as standard Light Grey Color, but can be delivered in other colors.

Insulation Material: ASTM E 84 /EN 13501:1  Fire rated Class A – (EN B-s1-d0).

Backside: Cement coated.

Resistant to Mold, Fungus, Moisture etc.

Non organic material, does not rot or degrade in humid environments and is not weakened when wet.

Dimension
Length Standard
Feet/mm
8’ (2400)
Width Standard/Max
Feet/mm
45"(1140)
Thickness standard
Inches
1.33” (34mm) – 3.11” (79 mm)
Tolerance Thickness
ASTM C 1185
+/- 1-2 %
Tolerance Length
ASTM C 1185
+/- 1 -2 %
Tolerance Width
ASTM C 1185
+/- 1 -2 %
Weight
pcs
45 lb (20 kg) to 65 lb (30 kg)

Fiber Cement Certification: FC-H20: (ICC AC 90 ESL report 1116)

Fire Properties
Fire Class Material
ASTM E 84
Flame spread – index 0
Fire Class Material
ASTM E 84
Smoke – index 0
Fire class material
ASTM E 136
Non combustible
Water Vapor Transmission
Water Tightness ¼” – ½”
ASTM C 1185
No water drops formed
Freeze Thaw Resistance
Freeze Thaw Resistance
ASTM C 1185
Type A grade II
Warm Water Resistance
Warm Water Resistance
ASTM C 1185
Pass
Heat Rain Resistance
Heat Rain Resistance
ASTM C 1185
Type A grade II
Hygroscopic Properties
Moisture Movement 30 to 90% RH
ASTM C 1185
0.10% - 0.12%
Water Absorption – anti water
< 5 %
PH value
PH
11
Bending strength MPa
Bending strength Dry
ASTM C 1185
>16
Bending strength Wet
ASTM C 1185
>10
Wall Applications
A
Thermo Panel
B
U Track
C
C studs
D
Insulation
Wall Applications
A
Thermo Panel
B
Plate
C
Studs/OSB
D